DAT CONTROLER® REMOTE 60 AT-2560 Early Streamer Emission air terminal (∆t 60µs), with remote verification
DAT CONTROLER® REMOTE 60: Early Streamer Emission air terminal (∆t= 60µs), with remote verification. Material: Stainless steel AISI 316L.
DAT CONTROLER® REMOTE 60: Early Streamer Emission air terminal (∆t= 60µs), with remote verification. Material: Stainless steel AISI 316L.
Features
- Advance time: 60 µs obtained according to the tests described in the standards NF C 17102 and UNE21186. It is the lightning rod with the largest possible protection radius, since according to this standard this is the longest advance time that can be applied to calculate the area protected by a lightning rod with an ignition device.
- AENOR product certification.
- Daily remote verification, with available data in real time at a web app using 2G/3G network.
- Tested current: 20 x 200kA + 5 x 250kA (10/350µs wave).
- Certificate of performance under rain (Insulation > 95% according to EN 60060).
- No external power supply required.
- Protection radius up to120 meters according to NF C 17102 and UNE21186.
- Web portal for daily information on status of air terminals.
- M2M communication.
Specifications
Reference | AT-2560 |
Length | 120 mm |
Width | 120 mm |
Height | 551 mm |
Weight | 5000 g |
Materials | AISI 316L stainless steel |
IP COde | IP67 |
Work temperature | -25°C to 88°C |
internal insulation | Polyurethane resin |
Fixing | M20 male thread |
Type of air terminal | Electropulsator (emits impulses) |
Advance time (ΔT) in certified striking | 60 µs |
Protection radius (m) | |
Height for protection radius |
2, 4, 6, 8, 10, 20, 60
|
Protection radius (m) for Level I |
31, 63, 79, 79, 79, 80, 80
|
Protection radius (m) for Level II |
35, 69, 87, 87, 88, 89, 90
|
Protection radius (m) for Level III |
39, 78, 97, 98, 99, 102, 105
|
Protection radius (m) for Level IV |
43, 85, 107, 108, 109, 113, 120
|
Tested current | 20 x 200kA + 5 x 250kA (10/350µs wave) |
Standard deviation ratio ESE/Simple rod: | <0.8 |
Standartd | Complies with NF C 17-102:2011; UNE 21186:2011; NP 4426:2013 |
Certifications and tests
- AENOR Product Certification Nr. 058/000005 in accordance with UNE 21186 standard.
- Withstand current certificate for 20 impacts of 100 kA, 10/350 µs wave (ITE).
- Tested current:20 x 200kA + 5 x 250kA (10/350µs wave).
- Certified advance time.
- Certificate of unalterable performance under rain applying the standard EN 60060-1:2012.
- Radius protection certificate and regulation compliance (NFC 17-102, UNE 21186).
- Certificate of compliance with the standards of Electromagnetic Compatibility (EMC).
- Certificate of conformity with radio equipment directive R&TTE.
- Certificate for use in explosive athmospheres (ATEX).
- Manufactured according to ISO 9001 and following ISO 14001 environmental management standard.
Diagram(mm)
Installation
ESE air terminal protection radius depends on its height related to the surface to be protected, its advance time ∆T and the protection level.
The installation of DAT CONTROLER® REMOTE air terminals should follow the standards NF C 17-102:2011, UNE 21186:2011 and NP 4426:2013.
The air terminal should be at least 2 meters higher than any object to be protected.
For correct operation of the remote testing, orient towards maximum solar gain, avoid shadows and obstacles and check GSM signal.
Summary
0
(0 Reviews)
Select a row below to filter reviews.
No customer reviews for the moment.