On-line IoT UPS double conversion tower/rack from 4 kVA to 10 kVA with FP=1 Efficiency and reliability for the protection of critical data The SLC TWIN RT3 series from Salicru comprises Uninterruptible Power Supply Systems (UPS/UPS) from 4 to 10 kVA, with excellent electrical protection features for critical server environments. Although their nature is to integrate into rack cabinets, they…
Quantity
Out-of-Stock

SALICRU 6B4AC000003 On-line IoT UPS double conversion tower/rack from 4 kVA to 10 kVA with FP=1 Efficiency and reliability for the protection of critical data The SLC TWIN RT3 series from Salicru comprises Uninterruptible Power Supply Systems (UPS/UPS) from 4 to 10 kVA, with excellent electrical protection features for critical server environments. Although their nature is to integrate into rack cabinets, they include all the accessories and adaptability to be arranged in a tower format. In models from 4 kVA, a power strip is included that can be mounted either in a rack arrangement or attached to the body of the UPS, if the vertical format is chosen. This power strip, also known as PDU (power distribution unit), extends the electrical connectivity of the equipment to the maximum, facilitating the quick connection/disconnection of the loads to be protected. In the direct interaction part with the user, a matrix screen has been chosen. (Dot matrix) that makes it easy to highlight important information in the center of the screen, unlike traditional LCD screens. Reliability, power density and immediacy of information have been 3 of the key elements in defining the SLC TWIN series RT3, considering that these 3 factors are the ones that best satisfy the user's demands today. Connectivity and vigilant protection The inclusion of an Ethernet port and the option of a Wi-Fi device allow the SLC TWIN RT3 series to be integrated into the IoT environment. Through the cloud, our NIMBUS APP and the website, developed entirely in the Connected Software department of SALICRU, offer maximum supervision of the status of the equipment, reception of information and alarms, execution of remote battery tests, ...The immediacy that connectivity provides us, directly ensures the continuity of the connected loads and, consequently, the continuity of the productivity associated with them. At the hardware level, an overvoltage cut-off device (OVCD), a detection system fan blocking, overtemperature detection, overload alarm and external battery detection system guarantee constant automated monitoring of our system. Improved Length In many cases, the depth of 19” rack cabinets is often a factor. This particularity has led us to consider as a key factor, in the design of the SLC TWIN RT3 range, the reduction of its dimensions in the Z axis, always maintaining the height of 2U x 19” on the front of the UPS. As a result, we offer a range of high power density, limited to only 600 mm in depth. The corresponding batteries are also supplied in a 3U format with also reduced depth. Multiple output options The SLC TWIN RT3 series has different connection options for loads. The equipment from 4 kVA, in addition to offering 2 IEC C13 quick-connect outputs and an input/output terminal block, are also delivered with a rackable power strip that has 8 additional outputs (6 x IEC C13 + 2 x IEC C19 ). The power strip has safety closing clips for correct fastening of the electrical connectors and can be mounted, using the supplied accessories, on the side of the UPS. Advanced internal temperature management SLC TWIN RT3 from 4 to 10 kW has two fan batteries to optimize the thermal conditions inside the equipment. The front battery acts as a drive, while the rear one extracts the air immediately. This double system incorporates variable speed fans to balance ventilation efficiency with energy consumption. The improvement of thermal conditions favorably affects the extension of the life of the components, while creating the appropriate environment for the equipment to carry out its functions. maximum performance. The precision in the engineering of this system has allowed the equipment to be maintained at optimal noise levels, under typical load conditions, despite the increase in air exchange capacity. Connectable Manual Bypass BM-R The quintessential option of this series is the external manual bypass module. This bypass offers us management of the connected batteries, the possibility of manipulating the connected UPS without having to interrupt the downstream network supply and, as the most important feature, it incorporates 2 groups of programmable outputs to assign to critical loads and secondary loads, conveniently. .This external module therefore has 4 IEC13 outputs, 2 IEC19 outputs, divided equally into two groups, and a terminal output. It can be mounted in rack format both on the front of the cabinet and on the back. It also comes with fixing ears that allow it to be folded down, without disassembling it, to be able to operate the connections on the back with maximum comfort. Not ending the palette of options there, there are also two metal supports that allow it to be mounted on the side of the equipment when the user has it in tower format. Extended autonomy option SLC TWIN RT3 maintains autonomy extension options through additional battery modules in 3U rack format. The modules are interconnected with each other and with the UPS through a solid Anderson aerial connector and an RJ45 cable, for intelligent management .The charging currents and bus voltage are selectable by the user, adapting as much as possible to the autonomy option available. For installations that require more current input in the battery charging cycle, there is the B1 range equipped with a high-capacity charger, maintaining the 2U format of the standard version. more satisfy the user's demands today.

Specifications

AC Output Type C13 coupler
Number of AC outlets 2 AC outlets
USB port Yeah
Port - RS-232 1
Emergency shutdown device Yeah
SmartSlot Yeah
USB port type MicroUSB
Ethernet LAN ports (RJ-45) 1
Broad 438mm
Depth 570mm
Height 220mm
Weight 55.6kg
Operating temperature range 0 - 50°C
Relative operating humidity 0 - 95%
Operating altitude 0 - 3000m
Battery Type Lead-Calcium (Pb-Ca)
Recharge time (90%) 3 hours
Input and output (I/O) ports HDMI
Display type LCD
Form factor Rack/Tower Mount or Rack/Tower Mount
Product color Black
Security EN IEC 62040-1
Feeding Alternating current
Output without power Yeah
UPS Topology Double conversion (online)
Output power capacity (VA) 6kVA
Output power 6000W
Operating input voltage (min) 110V
Operating input voltage (max) 276V
Input frequency 50/60Hz
Output operating voltage (min) 200V
Output operating voltage (max) 240V
Output voltage regulation 1%
input power factor 0.99
Output power factor 1
ECO mode Yeah
emergency shutdown Yeah
Voltage Output Total Harmonic Distortion 5%
Total Harmonic Distortion (TDH) (line load) 1%
Total Harmonic Distortion (TDH) (non-linear load) 5%
Noise level 55dB
Temperature Stress Compensation Yeah
Free of mantenimient Yeah
Output frequency 50/60Hz
Plug circuit breaker Yeah
Efficiency (online mode) 95%
Efficiency (ECO mode) 98%