Promax IC-090A Three-phase electrical networks analyzer with harmonics up to 3000 A

Promax IC-090A Three-phase electrical networks analyzer with harmonics up to 3000 A

Promax
promax-ic-090a
€2,940.30
€3,267.00
10%
Tax included

A suitable tool for low voltage electrical networks installers with TRMS measurements for both voltage and current. Includes power supply failures location, analysis of load profile and supply optimization. It allows transferring the data measurements to a PC via SD memory card.

Quantity
Available in 24/48h

A suitable tool for low voltage electrical networks installers with TRMS measurements for both voltage and current. Includes power supply failures location, analysis of load profile and supply optimization. It allows transferring the data measurements to a PC via SD memory card.

The three-phase power network analyser up to 3000 A with harmonics measurement model IC-090A provides to the installers (no matter if basic or specialists) a rugged instrument with a great capacity of analysis.

The IC-090A is the perfect instrument for low voltage electrical networks installers. It is fitted with a big, backlighted display that shows all the network parameters as well as the measurements taken by the instrument: True RMS (for both voltage and current), power supply failures location, analysis of load profile and supply optimization. A very intuitive user interface together with an ergonomic design conform a very easy to use tool.

It allows real-time datalogging in a SD memory card (included) to transfer it to a PC and perform data analysis and reports generation using Microsoft Excel.

  • V (phase to phase), V (phase to ground)
  • A (phase to ground) true power
  • kW (True Power)/ kVA / kVAR / PF (phase)
  • kW (True Power)/ kVA / kVAR / PF (system)
  • kWH / kVAH / kVARH / PFH (system)
  • Phase angle

Specifications

MEASUREMENTS
  • VAC, AAC
  • Power factor
  • Φ (Phase angle)
  • Frequency
  • Active (real) voltage, Apparent voltage
  • Reactive power
  • Watts hour (Active or reactive voltage hour)
  • Watts hour (apparent voltage hour)
  • AC harmonics (in percentage and magnitude)
  • AC current harmonics in pertentage
  • VAC or AAC peak value
  • VAC or AAC crest factor
  • Total harmonic distortion
SAFETY STANDARD IEC1010 CAT III 600 V
INCLUDED ACCESSORIES User manual, Test leads, Alligator clips, Clamp probe, AC to DC 9 V adapter, SD card (2 GB), Transport case

Accessories included

  • Instruction manual 1 u.
  • Test leads (TL88-4AT) 1 set (4 pcs.)
  • Alligator Clips (TL88-4 AC)
  • 1 set (4 pcs.)
  • Clamp probe (CP-1201) 3 pcs.
  • AC to DC adapter 9 V 1 u.
  • 1 x SD Card (2 GB)
  • Carrying case 1 u.