Bysecur BSC02980 24V - 4A power supply with box and space for 2 7Ah backup batteries (not included)
BSC02980
€86.70
€133.39
35%
Tax included
24V - 4A power supply with box and space for 2 7Ah backup batteries (not included)With high quality metal boxSpace for 2 7 Amp batteriesIndicator lights on the coverPower supply: 230VAC 50HzBattery connection cable (not included)
Bysecur BSC02980 24V - 4A power supply with box and space for 2 7Ah backup batteries (not included)
- 24V - 4A power supply with box and space for 2 7Ah backup batteries (not included)
- With high quality metal box
- Space for 2 7 Amp batteries
- Indicator lights on the cover
- Power supply: 230VAC 50Hz
- Battery connection cable (not included)
ELECTRICAL SPECIFICATION
MODEL ZBF-24-4A-7Ah Rev. R1.0/R1.1
PRODUCTION
Nominal DC voltage: Line mode 27.6V DC
Nominal DC voltage - battery mode 21 ÷ 27.6 V
Nominal current for charging 3.5A
Charging current range 0 ÷ 3.5A
Rated power for charging 96.6 W
Rated charging power 11.3 W
Total rated power 107.9 W
Voltage tolerance [3] ± 5%
Ripple and noise (max.) [2] 150mVP-P
BATTERY
Space for 24V / 7.2 ÷ 9Ah VRLA AGM battery - two 12V batteries connected in series
Nominal voltage 24 V
Loading parameters
Current voltage (max.)
0.41 A 27.6 V
INPUT
Voltage range 90-132 VAC, 180-264 VAC (switch selectable on PSU module)
Frequency range 47 ÷ 63Hz
Performance (typical) 86%
AC Current (Typical) 2.0A/115VAC, 1.2A/230VAC
Input current (typ.) 36A / 230VAC
OUTPUT PROTECTIONS Line mode Battery mode
Short circuit type: FS1 fuse blown on BUF module, recovers after fuse replacement
Overload
Range: 110-150% of full rated power Range: above 110% of full rated power
Type: Power supply module hiccup mode
and FS1 fuse blown in BUF module, recovers
After replacing the fuse and eliminating the fault
condition
Type: FS1 fuse blown in BUF module, self-recovery
After replacing the fuse and eliminating the fault
condition
Over voltage
Range: 105-150% of nominal DC voltage
Type: power supply module hiccup mode,
auto recovery
Without protection
Overheating
Range: <70 ° C Surrounding air temperature
and 100% charge
Type: PSU module shutdown, recover
after the fault condition is removed
Without protection
BATTERY PROTECTIONS
Short circuit type: FS1 (F5A) fuse blown on BUF module, recovers after fuse replacement
Reverse battery type (polarity): one time, no automatic recovery
Battery cut-off range: 21V±1VDC, relay cut off
WORK ENVIRONMENT
Working temperature -10 ° C ÷ + 45 ° C
Working humidity 20 ÷ 85% non-condensing
Storage temperature and humidity -20 ° C ÷ + 60 ° C, 10 ÷ 95% non-condensing
SAFETY and EMC REGULATIONS
Safety Standards Compliance with EN60950-1
IP/OP supported voltage: 3kVAC; IP/GND: 1.5kVAC; OP/GND: 0.5kVAC
EMC emissions Compliance with EN 55032
EMC Immunity Compliance with EN61000-4-2, -3, -4, -5, -6, -8, -11
OTHERS
Internal/External dimensions 285*280*80mm (W x H x D); 289*285*89mm (W x H x D)
Net/gross weight 2.1kg/2.3kg