Fermax 3233 RELAY BASIC DUOX PLUS
This relay allows the most basic and common functions to be carried out: opening a door, activating a light, etc.
For more advanced functions and not available in this relay, FERMAX has the DUOX PLUS relay ref. 3267.
Programming is very easy, even if the factory default parameters are already the ones desired by the installer, you won't even have to program anything. Connect and go.
Using jumper JP1, the relay can be programmed as:
Block Relay (Default value: block=00): Only the devices in that BLOCK can activate the relay (panels, guard unit or monitors/telephones)
General Input Relay: All users of the installation can activate the relay.
The relay can be programmed to activate with the following actions:
Door opening.
F1 (default activation parameter).
F2
Call from panel or guard unit.
The relay activation time can also be programmed: [1 s., 99 s.]. The factory default value is 4 s.
Technical specifications
DESCRIPTION
JP1: Work mode selector
• GE: GENERAL ENTRY mode
• BL: BLOCK mode
CONNECTION TERMINALS
• +12: 12 Vdc auxiliary output (max: 300 mA).
• C, No, NC: Potential free relay contacts. 250Vac / 30Vdc - 3A. Max.
• ON: LED (Green) indicating that the relay has been activated.
BUS INPUT: Terminal block for connection to the DUOX PLUS Bus.
PRG BUTTON: To enter PROGRAMMING mode and define the ACTIVATION TIME.
EXTERNAL PUSHBUTTON CONNECTIONS: By shorting BS and -, the relay will activate for the configured ACTIVATION TIME.
INDICATIVE LEDS:
• PWR (Red): Indicates that the device receives the necessary power to work.
• MODE (Blue): Indicates if the device is in PROGRAMMING mode and the phase of the procedure it is in.
QR TO THE USER GUIDE: scanning this QR with the mobile takes the installer to the product's technical manual.
TECHNICAL CHARACTERISTICS
Power supply: 18-24 Vdc
Consumption:
Standby: 1.2W
Relay ON: 7.2W
Operating temperature: [-5ºC, +40ºC]
Relative humidity: [5%, 95%]
Dimensions: 86 (height) x 106 (width) x 31 (depth) mm
Mounting on DIN 6 rail (including the lateral fixing brackets to be screwed, width 106 mm). Eliminating the lateral fixing supports for the screws the width is 89 mm (DIN 5).
PARAMETERS
VALUES
DEFAULT VALUE
GENERAL ENTRANCE / BLOCK
with jumper JP1 (GE/BL)
BL (with JP1)
BLOCK NO.
00-99
0
ACTIVATION COMMAND
Lock release, F1, F2, Call from panel or guard unit
F1
ACTIVATION TIME (Tact)
0-99 sec.
4 sec.
NOTE: if the factory default parameters are already those desired by the installer, you will not have to program anything. Connect and go.