Fermax 29001 TIMER
The timer has the following connections and controls:
Potential free relay for activation of the external device (C, No, Nc).
Potentiometers to adjust the activation time: minute adjustment potentiometer (P1) and seconds adjustment potentiometer (P2).
Timed activation pushbutton connection (S, -): activates the timer relay for the programmed time.
Button connection for Reset (R,-): Allows deactivating the timer before the end of the programmed time.
Button connection for direct activation (Ab, -): activates the timer relay when the button connected here is pressed.
Connection for activation by call (I1, I2): allows connecting the call and negative wire coming from the street panel (4+N installations) and activating the timer when making a call.
Technical specifications
Power supply: 9~14 Vac ;11~18 Vdc
Consumption:
With 12 Vdc power supply: 20 mA standby, 50 mA active.
With 12 Vac power supply: 50 mA standby, 110 mA active.
Maximum output values:
Power (resistive load): 1250VA or 150W
Voltage (resistive load): 125 Vdc, 380 Vac.
Maximum temperature: 0~+65ºC
Timing:
P1: from 0 to 6 minutes approximately.
P2: from 1 to 60 seconds approximately.
Activation by call:
Electronic call: 4Vpp~18Vpp.
Alternate call: 4Vac~12Vac.