Features | Value |
---|---|
Halogen free according to EN IEC 60754-2 | - |
Reaction-to-fire according to EN 13501-6: Flaming droplets/particles | None |
Cable height approx. | 12 mm |
Reaction-to-fire according to EN 13501-6: Smoke production | None |
Reaction-to-fire according to EN 13501-6: Class | None |
Number of pilot/reduced conductors | - |
Cable width approx. | 5 mm |
Nominal cross section pilot/reduced conductors | - mm² |
Weight | - kg |
Low temperature resistant according to EN 60811-504+505+506 | No |
Oil resistant according to EN IEC 60811-404 | No |
Conductor surface | Bare |
Material armouring | - |
Number of stranding elements | - |
Torsion resistant | No |
Reaction-to-fire according to EN 13501-6: Acidity | None |
Min. permitted bending radius, stationary application/permanent installation | - mm |
Min. permitted bending radius, moving application/free movement | - mm |
Min. permitted bending radius, moving application with forced guidance | - mm |
Shape of conductor | Round |
Specification material outer sheath | - |
Specification core insulation | - |
Colour outer sheath | Grey |
Number of strands per conductor | - |
Conductor resistance at 20 °C | - Ohm/km |
Halogen free according to EN IEC 60754-3 | - |
Strand diameter | - mm |
Low smoke according to EN IEC 61034-2 | No |
Nominal voltage U | 12 kV |
Stranding element | No |
Nominal voltage U0 | 12 kV |
Number of cores | 6 |
Screen | - |
Core identification | Other |
Suspension element | None |
Material core insulation | - |
Nominal cross section conductor | 0.16 mm² |
Halogen free according to EN IEC 60754-1 | - |
Flame retardant according to IEC 60332-3-24 (Cat C) | - |
Flame retardant according to IEC 60332-3-25 (Cat D) | - |
Conductor material | Copper |
Screen over stranding | None |
Screen over stranding element | None |
Outer diameter approx. | 2 mm |
Drain wire | - |
Flame retardant according to IEC 60332-3-22 (Cat A) | - |
Material outer sheath | - |
Flame retardant according to IEC 60332-3-23 (Cat B) | - |
Flame retardant according to IEC 60332-1-2 | - |
Max. conductor temperature | - °C |
Flame retardant according to IEC 60332-3-21 (Cat A F/R) | - |
Protective barrier | - |
AWG size | 26 |
Armouring/reinforcement | - |
Permitted cable outer temperature after assembling without vibration | - °C |
Permitted cable outer temperature during assembling/handling | - °C |
With protective conductor | No |
Core identification according to HD 308 S2 | - |
Max. tensile strength during installation | - kN |
Cable geometry | Flat |
Conductor category | Class 6 = very flexible |
Nominal cross section pilot/reduced conductors (AWG) | - |
Nominal cross section conductor (AWG) | - kcmil |